My thermostat is set to heat, but my heat pump isn't coming on. Why?

Last updated

If your thermostat is newly installed and the heat pump worked with the previous thermostat, check the following:

1. Verify that the thermostat is set to heat and is calling for heat, usually indicated by the words “heat on," a flame icon, or a shimmering sun icon. If the room temperature is below the heat set point, the thermostat display should indicate a call for heat.
2. Confirm that the circuit breakers are on.
3. If you installed the thermostat yourself, ensure that the wires are matched correctly and securely connected at the thermostat.
4. If you installed the thermostat yourself, verify that the thermostat is correctly configured to control a heat pump. The installation instructions for your thermostat show these settings.
5. If the heat pump runs in cool mode with a call for heat, verify that the configuration setting for the changeover is set correctly for your system. The configuration settings are shown in the installation guide for your thermostat. If you do not know whether your heat pump uses the changeover valve in heat or cool mode, call your professional HVAC contractor or the manufacturer of your heat pump.
6. If there are not separate wire connections to R and Rc on the thermostat, those terminals need a jumper. Some models use a small metal jumper and other models have a switch that needs to be set to "R".

If the same issue occurred with the previous thermostat, then the problem is most likely with your heat pump. Call a professional HVAC contractor if the above steps don't solve the issue.

CONTACT US

Message Resideo

MESSAGE US

Message us on Twitter for help with our products.

Monday through Friday:
9am to 6pm CDT
Saturday and Sunday:
9am to 5pm CDT

Live Chat with Resideo

CHAT US

Connect with an agent for quick assistance.

Monday through Friday:
9am to 8pm CDT
Saturday and Sunday
9am to 5pm CDT

Call Resideo

CALL US

Speak directly with an agent for help with our products.